Necessity of Air Cooling Tower / Dry Cooling Tower
Water is the most essential element of our life, About 97 percent of that is stored in ocean.
Of the remaining 3%, 2% are frozen ermanently as ice. What is left is what we have to work with.
And this precious and meager amount needs a lot of attention to perform its function properly in the
machines of civilization. Water plays a great role in industries. It is used as a coolant in various
machineries. In water cooling towers like FRP Tower or Timber Tower, huge loss of water due to
drift, evaporation, spray loss and blow down. It is now abundantly clear that water charges will go on
rising at well beyond inflation rates. So for that we are introducing the Air Cooling Tower / Dry Cooling Tower
for save the water.
1 Special Features of Air Cooling Tower / Dry Cooling Tower
1.1 Usage :
The Air Cooling Towers / Dry Cooling Towers are very compact and aerodynamically designed for Diesel Engines and LT & HT Circuits.
1.2 Very Less Water Conceptions:
The Air Cooling Towers / Dry Cooling Towers are air cooled equipment so just you fill very small quantity of water, after that it is not required additional water. Due to the closed circuit there is no evaporation loss. So our towers are save the water cent percent.
1.3 Filling Water :
You can fill any typeor quality of water. No need of water softening plant or treatment chemicals. In
first time just you fill small quantity of common drinking water.
1.4 No Scale formation
Due to closed circuit, same water will be circulated continually and no chance for evaporation so that
scale will not be separate from the water and it is not deposit at any where in the heat transfer area.
1.5 Desiging:
Our Towers are very compact and aerodynamically designed. There is no any restriction for the location
of the plant; atmospheric air is the cooling media. It cools the hot water and maintains the temperature
of process hot water at a particular level. It has designed for highest ambient temperature so we
could run the engine in 100% load even in peak summer. It has the fan and eectric motor to the water.
1.6 Energy Economy:
Our Towers are specially designed aerodynamically for power saving we are provide the mostat
controls to switch off the fan motors in the time of cold ambient temperature.
1.7 Maintenance :
Our Dry Cooling Towers are closed circuit. So no chance to mix dust, fly, living organisms and
dirt with process water. Air is the cooling media so there is no corrosion problem.
2. Technical Specifications of Dry Cooling Tower / Air Cooling Tower
2.1 Designing and Material Quality
The Dry Cooling Towers are having heat transfer area with good quality coppers and very high
quality of aluminium fins. Copper tubes are mechanically expended with coolers, it provides
smooth inner tube surface so there is no chance for pressure drop (our Cooler are tested at 350 PSI).
Coolers are favricated in heavy channels and using steel sheets. The finalized steel frame provides
stacking and shipping support and production against tube damaging.
2.2 High performance of Fan and Motors:
A new generation start of the art cooling fans the energy economy concept. It combination of performance
strength endurance and reliability designed aerodynamically for characteristic of the fan outlet
essences an optimum distribution of air across the " Cooler" giving an added benefit to the
system fans are dynamically balanced on computerized machine. And using IP55 / TEFC standard motors.
Difference between Air Cooling Tower and Water Cooling Tower
| Air Cooling Tower | Water Cooling Tower |
| Plant location restriction is not required | Water Source decides the location opf large plantsr |
| Scale for mations are impossible | Scale formation is unavoidable |
| Water consumption is not required | Huge loss of water due to evaporation, drift loss |
| No corrosions due to air | Steel parts in contact with water are corroded |
| Mixing of dust, dirt is not possible when processing of water | Water exposed to dust and dirt will be contaminated |
| Except fan and motors maintenance is negligible | Maintenance is required |
Note:
1. The motor HP may be changed due to the ambient temperature of Air Cooling media and temperature of the water.
2.Primary circuit inlet water temperature 80 C outlet water temperature 70 C. In secondary circuit inlet water temperature 66 C outlet water temperature 56 C.
3. Other applications and models please contact jc@thecoolingtowers.com